>> Information
S600-M is a portable multiparameter water quality sensor, used for water quality monitoring.
S600-M packages includes a water sensor, a handheld meter, a 5 meter cable and a rugged carrying case. Together with the water sensor, there are 4 common probes with 5 parameters at default, pH, Conductivity/Temperature, Dissolved oxygen and Turbidity.
S600-M water sensor can be installed with up to 4 probes, can measure water quality parameters including pH, ORP, Dissolved Oxygen, Conductivity/TDS/Salinity, temperature, and optical sensors and ISE sensors.
Optical electrode Options
Turbidity, Total Suspended Solid, Chlorophyll, Blue Green Algae, CDOM/FDOM
ISE electrode Options
Ammonia, Nitrate, Chloride, Fluoride, Calcium
>> Application
S600-M water sensor housing is made of Stainless steel 316, and all the sensors are made by Titanium alloy which is with higher corrosion-resistance. Here are some specific applications:
Surface water, lake, reservoir, river, stream
Underground water, well water
Sea water, estuary
Industrial water, Municipal water,
Water plant, water treatment
Drinking water
>> Characteristics
Automatic identification. Each probe is digital, easy for replacement;
High degree of integration, can choose sensors with different parameters;
Wiper design is also available, based on your requirements;
Light weight, small size, suitable for more application;
Cable with interlock protection,which is more stronger and safe.
>> Parameters
| Specification | Details |
| Size | Φ60mm*415mm ( length) |
| Weight | 1.5KG |
| Main Material | POM+316 Stainless Steel |
| O ring: viton ring+ rubber ring | |
| Cable: PVC | |
| Measuring parameters | Standard: Temperature, Conductivity, pH, Turbidity, Dissolved Oxygen |
| Optional: Depth, ORP, Chlorophyll, Blue-green Algae, NH4+, K+, TSS, Salinity and etc. | |
| Data Output | RS 485. Modbus; Bluetooth(Optional) |
| Power | DC 12~24V |
| Storage Temperature | -20~+60℃(pH/ORP storage temperature 0~60℃) |
| Working Temperature | 0~50℃ |
| Pressure Range | Sensor Probe ≤0.6Mpa; Sensor Body≤2Mpa |
| Cable Length | 5m standard cable, other length can be optional; |
| Guarantee Period | Sensor Body 12 months; pH/ORP probe 12 months; |
| Ion sensor: 6 months; DO membrane cap 6 months; |
| Conductivity | |
| Measuring principle | Four-electrode method |
| Measuring range | 0-200mS/cm |
| Measuring accuracy | 0-100: reading value±0.5% |
| 100-200: reading value±1% | |
| Resolution | 1μS/cm-100μS/cm (according to the range) |
| Temperature compensation | Yes |
| Working temperature | 0-50℃ |
| Storage Temperature | -20C~+60℃ |
| Calibration way | one or two point calibration |
| Temperature | |
| Measuring principle | Thermistor method |
| Measuring range | 0-50℃ |
| Measuring accuracy | ±0.2℃ |
| Resolution | 0.1℃ |
| Working temperature | -5C~+50℃ |
| Storage Temperature | -20C~+80℃ |
| Calibration way | one point calibration |
| PH | |
| Measuring principle | Electrode method |
| Measuring range | 0-14 |
| Measuring accuracy | ±0.1 |
| Resolution | 0.01 |
| Temperature compensation | Yes |
| Working temperature | 0-50℃ |
| Storage Temperature | 0-60℃ |
| Calibration way | two or three point calibration |
| ORP | |
| Measuring principle | Electrode method |
| Measuring range | -1999~+1999mV |
| Measuring accuracy | ±20mV ( standard solution) |
| Resolution | ±0.1mV |
| Temperature compensation | Yes |
| Working temperature | 0-50℃ |
| Storage Temperature | 0-60℃ |
| Calibration way | one point calibration |
| Turbidity | |
| Measuring principle | Scattered light measurement |
| Measuring range | 0.01-4000NTU |
| Measuring accuracy | 0-10NTU: ±0.1NTU |
| 10-100NTU: reading value±2% or ±0.1NTU the bigger one; | |
| 100-4000NTU: reading value±5% | |
| Resolution | 0-10NTU: 0.01NTU |
| 10-100NTU: 0.1NTU | |
| 100-4000NTU: 1NTU | |
| Temperature compensation | Yes |
| Working temperature | 0-50℃ |
| Storage Temperature | -20C~-60℃ |
| Calibration way | one or two point calibration |
| Dissolved Oxygen | |
| Measuring principle | Fluorescence method |
| Measuring range | 0-200% saturability 0-20mg/L |
| Measuring accuracy | 0-100%: <±1% |
| 100-200%: <±1.5% | |
| Resolution | 0.001mg/L-0.01mg/L (according to the range) |
| Temperature compensation | Yes |
| Working temperature | 0-50℃ |
| Storage Temperature | -20C~+60℃ |
| Calibration way | one or two point calibration |
| Depth | |
| Measuring principle | Pressure sensitive method |
| Measuring range | 200m ( effective measurement depth of the electrodes is 60m) |
| Measuring accuracy | <±0.05 %F.S |
| Resolution | 0.001m |
| Calibration way | one point calibration |
| Chlorophyll | |
| Measuring principle | Fluorescence method |
| Measuring range | 0-400ug/L or 0~100RFU |
| Linearity | R²>0.999 |
| Resolution | 0.01ug/L |
| Working temperature | 0-50℃ |
| Storage Temperature | -20C~+60℃ |
| Calibration way | one or two point calibration |
| Blue-Green Algae | |
| Measuring principle | Fluorescence method |
| Measuring range | 0-100ug/L or 0~100RFU |
| Linearity | R²>0.999 |
| Resolution | 0.01ug/L |
| Working temperature | 0-50℃ |
| Storage Temperature | -20C~+60℃ |
| Calibration way | one or two point calibration |