>> Information
S600-M is a portable multiparameter water quality probe, used for water quality monitoring.
S600-M packages includes a water probe, a handheld meter, a 5 meter cable and a rugged carry case. Together with the water probe, there are 4 common probes with 5 parameters at default, pH, Conductivity/Temperature, Dissolved oxygen and Turbidity.
S600-M water probe can be installed with up to 4 probes, can measure water quality parameters including pH, ORP, Dissolved Oxygen, Conductivity/TDS/Salinity, temperature, and optical sensors and ISE sensors.
Optical electrode Options
Turbidity, Total Suspended Solid, Chlorophyll, Blue Green Algae, CDOM/FDOM
ISE electrode Options
Ammonia, Nitrate, Chloride, Fluoride, Calcium
>> Application
S600-M water probe housing is made of Stainless steel 316, and all the sensors are made by Titanium which is with higher corrosion-resistance. Here are some specific applications:
Surface water, lake, reservoir, river, stream
Underground water, well water
Sea water, estuary
Industrial water, Municipal water,
Water plant, water treatment
Drinking water
>> Characteristics
Automatic identification. Each probe is digital, easy for replacement;
High degree of integration, can choose sensors with different parameters;
Wiper design is also available, based on your requirements;
Light weight, small size, suitable for more application;
Cable with interlock protection,which is more stronger and safe.
>> Parameters
Specification | Details |
Size | Φ60mm*415mm ( length) |
Weight | 1.5KG |
Main Material | POM+316 Stainless Steel |
O ring: viton ring+ rubber ring | |
Cable: PVC | |
Measuring parameters | Standard: Temperature, Conductivity, pH, Turbidity, Dissolved Oxygen |
Optional: Depth, ORP, Chlorophyll, Blue-green Algae, NH4+, K+, TSS, Salinity and etc. | |
Data Output | RS 485. Modbus; Bluetooth(Optional) |
Power | DC 12~24V |
Storage Temperature | -20~+60℃(pH/ORP storage temperature 0~60℃) |
Working Temperature | 0~50℃ |
Pressure Range | Sensor Probe ≤0.6Mpa; Sensor Body≤2Mpa |
Cable Length | 5m standard cable, other length can be optional; |
Guarantee Period | Sensor Body 12 months; pH/ORP probe 12 months; |
Ion sensor: 6 months; DO membrane cap 6 months; |
Conductivity | |
Measuring principle | Four-electrode method |
Measuring range | 0-200mS/cm |
Measuring accuracy | 0-100: reading value±0.5% |
100-200: reading value±1% | |
Resolution | 1μS/cm-100μS/cm (according to the range) |
Temperature compensation | Yes |
Working temperature | 0-50℃ |
Storage Temperature | -20C~+60℃ |
Calibration way | one or two point calibration |
Temperature | |
Measuring principle | Thermistor method |
Measuring range | 0-50℃ |
Measuring accuracy | ±0.2℃ |
Resolution | 0.1℃ |
Working temperature | -5C~+50℃ |
Storage Temperature | -20C~+80℃ |
Calibration way | one point calibration |
PH | |
Measuring principle | Electrode method |
Measuring range | 0-14 |
Measuring accuracy | ±0.1 |
Resolution | 0.01 |
Temperature compensation | Yes |
Working temperature | 0-50℃ |
Storage Temperature | 0-60℃ |
Calibration way | two or three point calibration |
ORP | |
Measuring principle | Electrode method |
Measuring range | -1999~+1999mV |
Measuring accuracy | ±20mV ( standard solution) |
Resolution | ±0.1mV |
Temperature compensation | Yes |
Working temperature | 0-50℃ |
Storage Temperature | 0-60℃ |
Calibration way | one point calibration |
Turbidity | |
Measuring principle | Scattered light measurement |
Measuring range | 0.01-4000NTU |
Measuring accuracy | 0-10NTU: ±0.1NTU |
10-100NTU: reading value±2% or ±0.1NTU the bigger one; | |
100-4000NTU: reading value±5% | |
Resolution | 0-10NTU: 0.01NTU |
10-100NTU: 0.1NTU | |
100-4000NTU: 1NTU | |
Temperature compensation | Yes |
Working temperature | 0-50℃ |
Storage Temperature | -20C~-60℃ |
Calibration way | one or two point calibration |
Dissolved Oxygen | |
Measuring principle | Fluorescence method |
Measuring range | 0-200% saturability 0-20mg/L |
Measuring accuracy | 0-100%: <±1% |
100-200%: <±1.5% | |
Resolution | 0.001mg/L-0.01mg/L (according to the range) |
Temperature compensation | Yes |
Working temperature | 0-50℃ |
Storage Temperature | -20C~+60℃ |
Calibration way | one or two point calibration |
Depth | |
Measuring principle | Pressure sensitive method |
Measuring range | 200m ( effective measurement depth of the electrodes is 60m) |
Measuring accuracy | <±0.05 %F.S |
Resolution | 0.001m |
Calibration way | one point calibration |
Chlorophyll | |
Measuring principle | Fluorescence method |
Measuring range | 0-400ug/L or 0~100RFU |
Linearity | R²>0.999 |
Resolution | 0.01ug/L |
Working temperature | 0-50℃ |
Storage Temperature | -20C~+60℃ |
Calibration way | one or two point calibration |
Blue-Green Algae | |
Measuring principle | Fluorescence method |
Measuring range | 0-100ug/L or 0~100RFU |
Linearity | R²>0.999 |
Resolution | 0.01ug/L |
Working temperature | 0-50℃ |
Storage Temperature | -20C~+60℃ |
Calibration way | one or two point calibration |