Home / Products / Water Monitoring Sensors / Multiparameter Sensors / Multiparameter Water Quality Sensor with Battery

loading

Multiparameter Water Quality Sensor with Battery

Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • S600-PRO

  • LEADMED

>> Information


S600-Pro is an integrated multi-parameter water quality instrument used for monitoring water quality. 

It can be installed with up to 6 probes (built-in pressure sensor) and 1 central wiper, can measure water quality parameters as below: Depth, Water level, Temperature, Conductivity, pH, ORP, Turbidity, Dissolved Oxygen, Chlorophyll, Blue-green Algae, fDOM, NH4+, NO3-, chloride ion Cl-, TSS, K+, Ca2+, COD and etc.

Equipped with alkaline batteries, suitable for unmanned deployment in the wild.


S600-Pro has a special self-cleaning design, equipped with self-cleaning components to eliminate bubbles and prevent microbial growth, and can be monitored in various water environments including rivers, lakes, oceans, reservoirs, industrial water and groundwater.


QQ20260109-154400QQ20260109-154419

QQ20260109-155228

>> Characteristics


Good reliability, can operate in an unattended environment for months without maintenance;

Sensors are calibrated digital sensors, can be automatically addressed, identified and connected, operation is simple;

Self-cleaning coating film and wiper structure design, ensure the measurement window clean, prevent microbial growth, reduce maintenance frequency;

Titanium alloy material, with higher hardness, lighter weight and more corrosion resistance;

No cable needed, supports wireless communication on various terminal such as PC and Pads, realize real-time data viewing by software;

Self-calibration, calibration parameters are stored in the sensor, each probe has a waterproof connector, easy to plug and replace;

The host is equipped with a large-capacity memory chip that supports measurements data storage;

Automatic identification, each probe is digital sensor, easy for replacement;

Replaceable D-cell battery design, especially for field work more convenient


>> Application


S600-Pro water sensor housing is made of Stainless steel 316, and all the sensors are made by Titanium alloy which is with higher corrosion-resistance. Here are some specific applications:

1. Surface water, lake, reservoir, river, stream

2. Underground water, well water

3. Sea water, estuary

4. Industrial water, Municipal water,

5. Water plant, water treatment

6. Drinking water


>> Parameters


Specification Details
Size Φ75mm*743mm ( length)
Weight 3.5KG
Main Material POM+Titanium Alloy
O ring: viton ring+ rubber ring
Cable: PVC
Waterproof Rate IP68
Measuring parameters Standard: Depth, Water Level, Temperature, Conductivity, pH/ORP, Turbidity, Dissolved Oxygen
Optional: Chlorophyll, Blue-green Algae,  fDOM,  NH4+, NO3-, chloride ion (CL-), COD and etc.
Data Output RS 485. Modbus; Bluetooth
Internal Storage 8M
Power DC 12V
Storage Temperature -20~+60℃(pH/ORP storage temperature 0~60℃)
Working Temperature 0~50℃
Pressure Range Sensor Probe ≤0.6Mpa; Sensor Body≤2Mpa
Cable Length 10m standard cable, other length can be optional;
Guarantee Period Sensor Body 12 months; pH/ORP probe 12 months;
Ion sensor: 6 months; DO membrane cap 6 months;


Depth
Unit Psi, bar, depth (m)
Measuring principle Pressure sensitive method
Measuring range 200m (0~10m, 0~60m for option)
Measuring accuracy <±0.05 %F.S@25℃
Resolution 0.01m
Response time T90<5s
Working temperature -5-50℃
Storage Temperature -20C~+80℃
Calibration way one point calibration


Conductivity
Measuring principle Four-electrode method
Measuring range 0-200mS/cm
Measuring accuracy 0-100: reading value±0.5%
100-200: reading value±1%
Resolution 1μS/cm-100μS/cm (according to the range)
Temperature compensation Yes
Working temperature 0-50℃
Storage Temperature -20C~+60℃
Calibration way one or two point calibration


Temperature
Measuring principle Thermistor method
Measuring range 0-50℃
Measuring accuracy ±0.2℃
Resolution 0.1℃
Working temperature -5C~+50℃
Storage Temperature -20C~+80℃
Calibration way one point calibration


PH
Measuring principle Electrode method
Measuring range 0-14PH
Measuring accuracy ±0.1PH
Resolution 0.01
Temperature compensation Yes
Working temperature 0-50℃
Storage Temperature 0-60℃
Calibration way two or three point calibration


ORP
Measuring principle Electrode method
Measuring range -1999~+1999mV
Measuring accuracy ±20mV ( standard solution)
Resolution ±0.1mV
Temperature compensation Yes
Working temperature 0-50℃
Storage Temperature 0-60℃
Calibration way one point calibration


Turbidity
Measuring principle Scattered light measurement
Measuring range 0.01-4000NTU
Measuring accuracy 0-10NTU: ±0.1NTU
10-100NTU: reading value±2% or ±0.1NTU the bigger one;
100-4000NTU: reading value±5%
Resolution 0-10NTU: 0.01NTU
10-100NTU: 0.1NTU
100-4000NTU: 1NTU
Temperature compensation Yes
Working temperature 0-50℃
Storage Temperature -20C~-60℃
Calibration way one or two point calibration


Dissolved Oxygen
Measuring principle Fluorescence method
Measuring range 0-200% saturability 0-20mg/L
Measuring accuracy 0-100%: <±1%
100-200%: <±1.5%
Resolution 0.01mg/L 
Temperature compensation Yes
Working temperature 0-50℃
Storage Temperature -20C~+60℃
Calibration way one or two point calibration


Chlorophyll
Measuring principle Fluorescence method
Measuring range 0-400ug/L or 0~100RFU
Linearity R²>0.999
Resolution 0.01ug/L
Working temperature 0-50℃
Storage Temperature -20C~+60℃
Calibration way one or two point calibration


Blue-Green Algae
Measuring principle Fluorescence method
Measuring range 0-100ug/L or 0~100RFU
Linearity R²>0.999
Resolution 0.01ug/L
Working temperature 0-50℃
Storage Temperature -20C~+60℃
Calibration way one or two point calibration


FDOM
Unit ppb ( equiv. QSE)
Measuring principle Fluorescence method
Measuring range 0-300 ppb QSE
Linearity R²>0.999
Resolution 0.01ppb
Response time T90<10s
Working temperature -5℃-~+50℃
Storage Temperature -20℃-~+80℃
Calibration way one or two point calibration


NH4+
Unit mg/L
Measuring principle Ion-selective electrode
Measuring range 0~200mg/L
Linearity ±10% or 0.5mg/L take the bigger
Resolution 0.01mg/L
Response time T90<60s
Working temperature 0-35℃
Storage Temperature 0~50℃
Suitable water level <15m
Calibration way two point calibration


NO3-
Unit mg/L
Measuring principle Ion-selective electrode
Measuring range 0~200mg/L
Linearity ±10% or 0.5mg/L take the bigger
Resolution 0.01mg/L
Response time T90<60s
Working temperature 0-35℃
Storage Temperature 0~50℃
Suitable water level <15m
Calibration way two point calibration


CL-
Unit mg/L
Measuring principle Ion-selective electrode
Measuring range 0~200mg/L
Linearity ±10% or 0.5mg/L take the bigger
Resolution 0.01mg/L
Response time T90<60s
Working temperature 0-35℃
Storage Temperature 0~50℃
Suitable water level <15m
Calibration way two point calibration


COD
Unit mg/L
Measuring principle ultraviolet absorption
Measuring range 0.1~200mg/L ( equiv. KHP)
Accuracy ±2% or 0.5 mg/L take the bigger(equiv. KHP)
Resolution 0.1mg/L (equiv. KHP)
Response time T90<60s
Working temperature 0-50℃
Storage Temperature -20℃~+80℃
Calibration way one or two point calibration


Product Category

Leadmed Technology is a high-tech enterprise focused on water quality sensors and online water monitoring systems located in Beijing China.

QUICK LINKS

PRODUCTS CATEGORY

CONTACT US

Phone: +86-60203018
E-mail: sales@lmwatersensors.com
WhatsApp: +8613466752011
Skype: +86-13466752011
Add: Room510 Building A, East No.2 Beixing Road, Daxing District, 100162, Beijing, China
Copyright © 2025 Beijing Leadmed Technology Co., Ltd. All Rights Reserved. | Sitemap | Privacy Policy